top of page

Warranty Registration

Applicator:

Loading...

Checklist

General

Comply*

Substrate readiness form completed.

Project signoff form completed

The project has been installed in accordance to specification

All non standard details installed are pre-approved specifications

Any damage to membrane sheet repaired.

Roof / Deck Areas

Comply

Cap sheet and basesheet fully bonded together, no areas of delamination.

Roof drains & overflows installed to specification and watertight.

Gutters correctly and neatly installed, particularly the internal corners.

Gutters and outlets have been floodtested.

Cap sheet and base sheet laps offset satisfactorily. No three layer lap build-ups.

Overall installation free of wrinkles, creases and splits.

Nuravents installed to specification.

Tanking Areas

Comply

Mortar/concrete fillets fitted to all internal junctions and corners chamfered at a 45° radius.

All corners and upstands incorporate reinforcing or underflashing.

Under-slab membrane extends beyond footing and carefully protected until vertical membrane installed.

Bleed visible on all joints.

Junction of the floor and wall membranes installed to specification fully bonded and watertight.

Membrane termination completed to approved detail.

Specified drainage system installed below footing as per specification.

Membrane protection boards installed correctly.

Car Parking Membrane Areas

Comply

Underflashings installed to all corners and upstands (pay attention to parapets, gutters, junctions) All upstands overlaid with Nuraply.

Membrane is watertight and ready for the installation of the trafficable topping.

Upload
Max: 3 Documents

Important:

A warranty is a legally binding document that will place obligations on Nuralite Group Ltd. By completing this form, requesting a warranty and distributing the warranty to your customer you undertake that:

  • The products used have been sourced solely from Nuralite to provide a complete waterproofing solution.

  • All installation procedures have been performed in accordance with the printed technical information provided by Nuralite Group Ltd.

  • You will pay in full for all the products purchased.

preloading image

Registered Warranties

Max 20 most recent warranties shown. Click on row to download warranty.

Building Name

Address

Owner

Architect

Building Consent

Installed

System

Downloads

RESIDENTIAL

-

XUE TRUSTEE BLTD

17 Feb 2026

-

-​

RESIDENTIAL

-

RAYE DEVELOPMENTS LTD

2 Nov 2025

-

-​

14A Withiel Drive, Epsom, Auckland 1023 (Lot 2)

-

Fu Yu Feng Huang and A+A Develop Limited

BCO10366924

23 Oct 2025

-

-​

-

Sam & Shida Alavi

BCO10400625

17 Feb 2026

-

-​

-

Sam Shirazi

7 May 2026

-

-​

Lot 2 DP 209844

-

Pinewoods Motor Park Limited

BCO10389138

16 May 2025

-

-​

Moke Lake House

-

GERMAINE JOBLIN, BM INDEPENDENT TRUSTEE, PAUL ANTONY JOBLIN

PATTERSON ASSOCIATES

BC230624

30 Oct 2025

-

-​

Moke Lake House

-

GERMAINE JOBLIN, BM INDEPENDENT TRUSTEE, PAUL ANTONY JOBLIN

PATTERSON ASSOCIATES

BC230624

20 Mar 2026

-

-​

-

Jordan Saville & Catherine Crowley

Artektus Architecture

BC 250550

20 Sept 2025

-

-​

-

Rebekah Armer

351117

13 Jan 2026

-

-​

Moore Wilson Building

-

Nick Wilson

9 Feb 2026

-

-​

Lansdowne Park Retirement Village.

-

Lansdowne Park Retirement Village.

4 May 2026

-

-​

Lansdowne Park Retirement Village.

-

Lansdowne Park Retirement Village.

11 May 2026

-

-​

Block B

-

Tauranga Community Housing Trust

350326

8 May 2026

-

-​

Block A

-

Tauranga Community Housing Trust

350328

8 May 2026

-

-​

-

Greg Crean & Deborah Bryant

BCO10347604

20 Oct 2022

-

-​

LOT 3 DP 107689

-

Mark & Debbie Groenewegen

BC010391962

20 Oct 2025

-

-​

RESIDENTIAL

-

HOUBO ZHOU

15 Mar 2026

-

-​

House

-

Montague

5 May 2026

-

-​

Residential

-

Joseph Maurovich

Bco10355858

2 May 2025

-

-​

bottom of page