With the new changes to NZBC Clause H1, many designers are wondering the best way to specify a compliant membrane roof on a commercial project? As flat roof experts with over 55 years experience in the industry, we offer a system solution that make achieving H1 simple.

On the 3rd November 2022, MBIE made fundamental changes to Clause H1 which relates to energy efficiency and the thermal performance of roofing elements in particular insulation.

Climate Zone 1 2 3 4 5 6
Was R1.9 R1.9 R1.9 R1.9 R1.9 R1.9
Now R3.5 R4 R5 R5.4 R6 R7

 

The minimum roof R-Value has been increased in buildings over 300sqm and is shown in the above table. With these considerable changes, we have seen a significant increase in queries to our technical team via phone and email, as well as through the Live Chat function of our website. The queries all have a similar subject - how can we ensure we meet the new R-Values in our roof designs?

 

Nuralite have a solution that has been tried and tested in the market for over 15 years. Our CodeMark Certified Nuratherm Warm Roof system can ensure you meet and exceed H1 requirements. 

0,022W/(m.K) 50 60 70 80 100 120 140 150 160
R- Value R2.25 R2.70 R3.15 R3.60 R4.55 R5.45 R6.35 R6.80 R7.20